Vopseaua antivegetativa contine solventi, rasini, pigmenti si aditivi.
Pelicula uscata prezinta o rezistenta deosebita la apa si reduce substantial dezvoltarea vegetatiei marine si fixarea crustaceelor pe partea submersa a navelor maritime, sau ambarcatiunilor pentru agrement.
Recomandata in mod expres barcilor si ambarcatiunilor care navigheaza in apa sarata.
Disponibila in culori alb, albastru, negru, gri, rosu si verde - ambalaj de 2.5litri
Acoperire: 7 mp/750ml si 23.5 mp/2.5lt
Fisa tehnica: www.marine-shop.ro/img-360/Interspeed_Ultra_-_UK.pdf
Preparation |
PREVIOUSLY ANTIFOULED SURFACE:
In Good Condition: Rinse with fresh water and allow to dry. If old antifouling is incompatible or unknown, seal with Primocon.
In Poor Condition: Use Interstrip to remove all traces of antifouling.
PRIMING: All preparation for bare substrates is covered on the appropriate primer datasheet.
BARE GRP: Gelshield 200 for osmosis protection, or Primocon.
STEEL/IRON: Prime with Interprotect or Primocon.
LEAD: Etch Primer followed by Interprotect or Primocon.
WOOD: Preserve, if required, with Intertox. Prime with Interprotect or Primocon. |
|
|
Method |
Apply two coats per season. |
|
|
Hints |
Mixing Stir well before use.
Thinner YTA085 Thinners No.3
Thinning Thinning is not recommended.
Cleaner YTA085 Thinners No.3
Other True colour will develop after immersion. Take care to apply all the paint calculated even if it means applying an extra coat. It is important for performance to apply the correct thickness. |
|
|
Some Important Points |
To prevent premature failure, ensure the correct amount of paint is applied using the coverage as a guide. Product temperature should be minimum -5°C and maximum 35°C. Ambient temperature should be minimum -5°C and maximum 35°C. Substrate temperature should be minimum 1°C above dew point and maximum 35°C. |
|
|
Compatibility/Substrates |
GRP, Wood, Steel/Iron, Lead. Not suitable for use over Aluminium/Alloy substrates or zinc sprayed surfaces. Can be applied direct over most types of antifoulings, provided they are in sound condition. |
|
|
Number of Coats |
2-3 by brush/roller |
|
|
Coverage |
(Theoretical) - 10.50 (m²/lt) by brush |
|
(Practical) - 9.40 (m²/lt) by brush |
|
|
Recommended DFT |
43 microns dry |
Recommended WFT |
96 microns wet |
|
|
Application Methods |
Brush, Roller , AIRLESS SPRAY NOT RECOMMENDED |